Input voltage (V) |
AC400±10%(3P+N+PE) |
Max. input current (A) |
≤581 |
Rated frequency (Hz) |
50±5% |
Power factor |
≥0.99 |
Total Rated power (kW) |
360 |
Output voltage (V) |
DC200-1000 (DC50-1000 for China) |
Output current of single gun (A) |
0-500 |
Voltage regulation accuracy |
≤±0.5% |
Steady current accuracy |
≤±1% |
Current - Unbalance |
≤5% |
Ripple peak factor |
≤±0.5% |
Efficiency |
≥0.94 |
No. of charging terminals |
2 |
No. of charging connectors |
2 |
Cable length (m) |
5 |
Connector Type |
CCS2 or GB/T |
Cooling (for connectors) |
liquid cooled |
Charging mode |
two connectors charging simultaneously, alternately or on smart power distribution |
Standards |
PLC, IEC 61851; CAN, GB/T27930-2015 |
HMI |
touch screen |
Metering |
DC watt-hour meter to measure the output power |
Communication |
Ethernet |
Installation |
Floor standing |
Dimensions (W×D×H:mm) |
840 × 880 × 2000 (host) |
650 × 600 × 2000 (terminals) |
|
IP Level |
IP54 (Outdoor) |
Cooling |
Forced air cooled |
Ambient temperature (℃) |
-30 to 50 (normal output); 50 to 75 (derating output) |
Storage temperature (℃) |
-40 to 75 |
Humidity |
5%-95% no frost |
Altitude (m) |
≤2000 (full load output) |